LOTUS XS 230 V horizontal continuous mixer / Part 2 Overview, operation and service
Operation
1
2
3
In case of danger proceed as follows:
1. Immediately press the EMERGENCY STOP pushbutton (1) or the
red "OFF" pushbutton (2).
2. Disconnect the power supply and remove the connection cable (3).
3. Inform responsible person at the operational site.
4. If necessary call for medical assistance and fire brigade.
5. Recover persons from the danger zone, initiate First Aid measures.
6. Keep access routes free for emergency vehicles.
7. If the severity of the emergency permits, inform the competent
authorities.
8. Assign specialised personnel with the troubleshooting.
After the rescue operations
WARNING
Danger to life from premature reactivation!
On reactivation there is danger to life for all persons in the
danger zone.
Ensure that the danger zone is clear before switching
the machine back on.
Check the system before reactivation and ensure that
all safety equipment is installed and functional.
9. Check the system before reactivation and ensure that all safety
equipment is installed and functional.
5.5
Putting the machine into operation
5.5.1
Feeding material to the machine
1
Figure 32: Switching on the machine
1. Switch the machine on by pressing the green "ON" pushbutton (1).
page 30 / 48