LOTUS XS 230 V horizontal continuous mixer / Part 2 Overview, operation and service
Operation
5.11
Measures to be taken in case of water outage
NOTE
Water can be supplied to the machine from a container by
means of suction strainer (item no. 00136619).
5.12
Ending work / cleaning the machine
5.12.1
Cleaning
Clean the machine daily at the end of work and in case of
extended breaks.
NOTE
Water can enter sensitive machine parts!
Before cleaning the machine cover all openings in
which no water must enter for safety and functional
reasons (e.g.: electric motors and control cabinets).
Remover the covers completely after cleaning.
5.12.2
Secure against restarting
WARNING
Danger to life from unauthorised restarting!
When working with the machine there is the risk that the
energy supply is switched on without authorisation. This
poses a danger to life for the persons in danger area.
Before starting work, switch off all electrical power
supplies and secure them against being switched back
on again.
If the protective covers are removed for cleaning
purposes, it is essential that they be properly reat-
tached when work is finished.
5.12.3
Removing the mixing tube
2
1
Figure 38: Remove connection cable
1. Disconnect the power supply, remove the connection cable (1).
NOTE
The safety catch (2) on the mixing tube only allows the
mixing tube to be removed once the connection cable (1)
has been unplugged on the machine.
page 33 / 48