LOTUS XS 230 V horizontal continuous mixer / Part 2 Overview, operation and service
Maintenance
6.4.2
Strainer screen in the water inlet
Figure 46: Strainer screen in the water
inlet
Implementation by operator.
1. Remove the strainer screen from the Geka coupling.
2. Clean the strainer screen.
3. Replace the screen if dirt is severe.
4. Reinsert strainer screen.
Screen for Geka coupling:
Item no. 20152000
6.5
Actions after completed maintenance
After finishing the maintenance works and prior to switching on the
machine, the following steps have to be carried out:
1. Check all previously loosened screw connections for secure fit.
2. Check if all previously removed safety systems and covers are
properly reinstalled.
3. Ensure that all tools, materials and other equipment used have
been removed from the work area.
4. Clean the work area and remove any spilled materials such as
liquids, processing material or similar.
5. Ensure that all safety systems of the installation work perfectly.
6.6
Periodic inspection/expert inspection
Construction machinery has to be inspected for safe working
condition in accordance with the operating conditions and the oper-
ational requirements as needed, however at least once a year by
an expert.
Pressure vessels have to undergo the prescribed expert inspec-
tions.
The inspection results have to be documented and kept at least
until the next inspection.
page 41 / 48