Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Technical data
Electrical - 400V
Detail
Value
Unit
Voltage, three-phase current 50
Hz
400
V
Power consumption, max.
18
A
Fuse protection, minimum
3 x 25
A
Power input, max.
7.5
kW
Speed pump motor approx.
385
Rpm
Speed star wheel motor
12
Rpm
2.4
Capacity values, SD 6–3 SLIMLINE pump unit
SD 6–3 SLIMLINE pump output
Detail
Value
Unit
Pump capacity, approx.
17
l/min at
385 rpm
Operating pressure, maximum
20
bar
Maximum grain size
2
mm
Feed range
*
, max. with 25 mm
Ø
15
m
Feed range
*
, max. with 35 mm
Ø
20
m
*
Reference value depending on conveying height, pump condition
and version, mortar quality, composition and consistency
Compressor output DELTA 2
Detail
Value
Unit
Compressor output
0.180
Nm³/min
2.5
Sound power level
Guaranteed sound power level L
WA
95 dB(A)
2.6
Vibrations
Weighted effective value of acceleration to which the upper body parts
are exposed <2.5 m/s²