Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Description
4.5.2
Control box item no. 00254651
6
4
5
3
2
1
7
8
9
10
11
12
[1]
Main reversing switch is also emergency-stop switch
[2]
Water supply button
[3]
Selector switch booster pump "manual-0-automatic"
[4]
Control lamp operation 400V
[5]
Control lamp operation 230V
[6]
Main terminal
[7]
Dummy connector / connection for remote control
[8]
Yellow control lamp, wrong direction of rotation
[9]
Red control lamp, motor protection switch activated
[10] Pushbutton for control voltage "ON/ OFF"
[11] Pump motor selector switch
[12] Selector switch star wheel
15
14
13
Figure 12: Assembly unit control box
[13] Safety socket, controlled for connection of booster pump
[14] Safety socket for air compressor connection
[15] Connection of pump motor
NOTE
In 230V operation, switch off the booster pump. The 16A
fuse could trip due to the current draw of the machine.
page 22 / 80