Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
5.3.3.2 Connecting the power supply 400V
Figure 34: Connecting the power
supply
1. Connect machine to three-phase network 400V.
DANGER
Danger to life from electric current!
The electrical connection must be fused correctly:
Only connect the machine to a power source with
an approved RCD (residual current device) of type A
(30 mA).
The machine can be switched to 230V, 1 phase and oper-
ated, although it is connected to a 400V, 3 phase supply.
Benefits:
The motor speed can be controlled via the poten-
tiometer.
Disadvantage:
As the machine is controlled via the frequency
converter, the gear motor no longer reaches its full
capacity (maximum 4 kW).
5.3.3.3 Connecting the individual connectors
1
2
3
Figure 35: Power connections
WARNING
Danger to life from rotating parts!
Improper operation may lead to serious damage to
persons or property.
The respective drive (motors) must be operated only
with the control box of the machine.
1. Connect the power supply for the booster pump (1).
The booster pump is necessary if the water pressure falls
below 2.5 bar during running operation of the machine.
2. Connect the power supply for the air compressor (2).
3. Connect the power supply for pump motor (3).
page 35 / 80
Summary of Contents for 00260621
Page 77: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 77 80...
Page 78: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 78 80...
Page 79: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 79 80...