Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
5.3.4
Connecting the water supply
1
2
Figure 36: Closing the drainage cocks
1. Close the water draining cocks (1) at the water fitting.
2. Close the water sampling valve (2).
3. Close the water drain cock on the booster pump.
5
4
3
Figure 37: Connecting the water
4. Clean the water hose (3) from the water supply and bleed.
5. Connect the water hose (3) to the water inlet (4).
6. Remove the water hose (5) from the mixing tube.
7. Open the water tap from the water supply line.
NOTE
Use only clean water free of solids. The minimum pres-
sure is 2.5 bar when the machine is running.
Observe the Drinking Water Protection Ordinance in
Part 1
NOTE
Never let the pump run dry as this reduces the service life
of the pump.