Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
5.3.6.2 Connecting the mortar hose
1
2
Figure 46: Connecting the mortar hose
1. Connect the mortar hose (1) to the mortar pressure gauge (2).
NOTE
Ensure clean and correct connection and tightness of
the couplings! Dirty couplings and rubber seals are not
watertight, and water might leak under pressure inevitably
leading to blockages.
2. Lay mortar hoses with a radius large enough so that the hoses do
not kink.
3. Carefully secure risers so that they do not tear away from their own
weight.
3
Figure 47: Switching on
4. Turn the pump motor selector switch (3) to "right" position.
5. Allow the machine to run until all the wallpaper paste has emerged
from the end of the mortar hose.
6. Collect the wallpaper paste in suitable container and dispose of as
per regulations.
7. Turn the pump motor selector switch (3) to the "0" position.
5.3.7
Compressed air supply
5.3.7.1 Connecting the air hose
1
Figure 48: Connecting the air hose
1. Connect compressed air hose (1) at the air manifold.
WARNING
Never undo hose couplings while the compressed air
hose is pressurised.
page 40 / 80
Summary of Contents for 00260621
Page 77: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 77 80...
Page 78: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 78 80...
Page 79: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 79 80...