Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
Figure 52: Delivery hood
Feeding with delivery hood
Item no. 20600500
Fit the delivery hood instead of the grille cover.
WARNING
Risk of injury at the star wheel!
Do not open the delivery hood during the operation of
the machine.
Before opening, turn off the master switch/main
reversing switch and interrupt the power supply.
Figure 53: Injection hood
Feeding with injection hood:
Item no. 20600213
Fit the delivery hood instead of the grille cover.
WARNING
Risk of injury at the star wheel!
Do not open the machine during pneumatic conveying.
Before opening, turn off the master switch/main
reversing switch and interrupt the power supply.
NOTE
First feed material to the mixing pump G 4 X. Pull the
dummy connector or switch off the machine using pres-
sure control air. Start your work only when the level
sensor indicates full.
5.3.9
Booster pump (accessories)
Electrical system
WARNING
Danger due to electrical voltage!
Connect the pump only to plug sockets with PE contact.
For increased safety we recommend an RCD with a GFCI
switch with a rated residual current of 30 mA for the circuit
to which the pump will be connected. This applies in
particular for installation close to water tanks, ponds, etc.
Line connection
NOTE
Ensure that the suction line or intake line is connected at
the marked position.
If the pump is operated in suction mode, ensure that the
suction line is kept as short as possible.
page 42 / 80
Summary of Contents for 00260621
Page 77: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 77 80...
Page 78: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 78 80...
Page 79: ...Mixing pump G 4 X FU 230 400V Part 2 Overview operation and service Disposal page 79 80...