Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
Figure 72: Strainer
5. Open and empty strainer.
NOTE
Make sure that the water fully flows out of the water mani-
fold.
5.12.1
Blowing the water manifold dry
2
1
3
Figure 73: Connecting the air hose
1. Connect air hose (1) with Geka coupling and EWO coupling to the
compressed air flange (2) and to the water inlet (3).
7
4
8
5
6
Figure 74: Blowing the water manifold
dry
2. Turn the star wheel selector switch (4) to the "0" position.
3. Turn the booster pump selector switch (5) to the "0" position.
4. Turn the pump motor selector switch (6) to the "0" position.
5. Turn the main reversing switch (7) to position "I".
6. Switch on the air compressor using the green toggle switch.
7. Press and hold the water flow button (8) for approx. 15 seconds.
8. The water is now blown out of the manifold with compressed air.
9. Switch off the air compressor using the green toggle switch.
10.Turn the main reversing switch (7) to position "0".
NOTE
Make sure that the water fully flows out of the water mani-
fold.