Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Operation
5.13.5
Connecting the water hose
1
Figure 79: Connecting the water hose
1. Connect the water hose (1) to the mixing tube.
5.13.6
Cleaning the mixing tube
1
Figure 80: Opening the motor tilt flange
1. Open the quick closure at the motor tilt flange and tilt the motor.
2. Remove the mixing shaft (1) and clean it.
5.13.6.1 Inserting the mixing tube cleaner
1
2
Figure 81: Inserting the mixing tube
cleaner
1. Take the mixing tube cleaner (1) and cleaning shaft (2) from the
tool box.
Insert the mixing tube cleaner (1) into the mixing tube with
the scrapers pointing downward.
NOTE
When inserting the cleaner shaft ensure that the cleaner
shaft engages correctly in the drive dog in the head of the
rotor and when closing the motor flange.