Mixing pump G 4 X FU 230/400V / Part 2 Overview, operation and service
Maintenance
6.4.5
Setting value pressure switch water
1
Figure 99: Pressure switch water
Pressure switch
water (1)
Machine switches
"ON"
Machine switches
"OFF"
Water
2.2 bar
1.9 bar
6.4.6
Setting value pressure switch air
1
Figure 100: Pressure switch air
Pressure switch air
(1)
Machine switches
"ON"
Machine switches
"OFF"
Air
0.9 bar
1.2 bar
6.4.7
Setting value pressure switch air compressor
Air compressor
switches "ON"
Air compressor
switches "OFF"
Compressor 2.5 bar
3.1 bar
6.5
Adjusting the locking lever
1
2
3
Figure 101: Eccentric bushing
By turning the eccentric bushing (1) with the special
wrench (2) in the tool bag, the locking lever (3) can be
adjusted.
1. Loosen locking lever and turn eccentric bushing.
2. Close the locking lever and check if this action closes the mixing
tube again tightly.