AV1000 with Handle 230V 50Hz Safety – Overview – Operation – Spare Parts Lists
Initial operation, filling the pump
2021-05-12
25
Fig. 4: Mortar pressure gauge
The pump must be installed in a horizontal position.
Both the suction line (1) and the pressure line (2) must be
connected before the pump is put into operation. Pay attention to
adequate dimensioning of both lines.
At least 1" for the suction line
At least 3/4" for the pressure line
Ensure that the hose is completely air-tight and that the end is
immersed in the liquid to be pumped to avoid drawing in air.
Fig. 5: Inlet strainer with filter screen,
Article No. 00006906
The end of the suction line (3) must be fitted with an inlet strainer
with filter screen and integral non-return valve.
An additional fine filter in the suction line is recommended.
NOTE!
The delivery of the pump decreases with increasing
suction line length. Connect the high pressure
pump as close as possible to the water supply
point (pressing is better than sucking).
Fig. 6: Prefilter AV1000 cpl.
Article No. 00130219
Empfohlen wird ein zusätzlicher Vorfilter in der Saugleitung, um
Fremdkörper von der Pumpe abzuhalten.
3
2 1