AV1000 with Handle 230V 50Hz Safety – Overview – Operation – Spare Parts Lists
Initial operation, filling the pump
26
2021-05-12
When all these points have been observed, the pump can be
switched on. Depending on the length of the suction hose, priming
may take a few seconds. If the pump is still not delivering after a
few minutes, this may have one of the following causes:
There is still air in the pump and the pump has to be completely
filled with water again.
The suction line is not air-tight and the pump is drawing in air.
The suction-side screen is clogged.
The suction hose is kinked.
The maximum suction head is exceeded.
Important!
The pump must not be allowed to run dry in order
to avoid damage.
Basic information
WARNING!
Danger of injury due to improperly performed
maintenance work!
Improper maintenance can lead to serious injuries
or equipment damage.
Therefore:
– Ensure there is adequate space for assembly
before starting any work.
– Keep the assembly area clean and tidy. Loose
components and parts in the operating area can
cause accidents.
– If components are removed, make sure they are
properly reassembled with all fastening
elements.
Electrical system
DANGER!
Danger of death due to electric current!
Contact with live components can lead to death or
serious injury. Live electrical components can
move uncontrollably and cause serious injury.
Therefore:
– Before starting work, switch off the electrical
power supply and secure it against being
switched back on again.