Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Intended use of fitting block
28
2021-02-10
21 Intended use of fitting block
21.1 Purpose of fitting block
The equipment has been designed and constructed only
for the intended use described below.
Application range!
Primary use for water and neutral, non-adhesive
liquids. Also suitable for air and neutral non-
flammable gases.
Maximum operating pressure (initial pressure)
16 bar.
After-pressure infinitely adjustable from 1.5 to
6 bar.
Smallest possible initial pressure 2.5 bar.
Minimum pressure gradient (initial/after-pressure)
1 bar.
Maximum media and ambient temperature 75°C.
Installation position unimportant, preferably vertical.
21.2 Purpose of solenoid valve
Application range!
Solenoid valves for liquid and gaseous media,
aggressive or neutral, can be used in various
temperature and pressure ranges
Type 6213 is a 2/2-way straight-through solenoid
valve, closed without power, with a positively
coupled diaphragm system. It switches from 0 bar
and is universal in use for liquids. A minimum
differential pressure of 0.5 bar is necessary for
complete opening.
21.3 Purpose of flowmeter
Application range!
The flowmeter serves for measuring the volume of
transparent liquid and gas flows in closed pipes.
Optionally, the devices can also be used for
flow monitoring.