Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Preparation
2021-02-10
35
29 Preparation
Before operating the machine, carry out the following work steps as
preparation:
Fig. 35: Danger of injury
Danger!
Rotating pump shaft!
Danger of injury when reaching into
the material container.
Therefore:
The protective grille should not be removed
while preparing or operating the machine.
Never reach into the machine while it is running.
29.1 Connection to the 400 V power supply
Fig. 36: Power supply
Connect the machine (1) to three-phase current with 400 V.
DANGER!
Danger of death due to electric current!
The electrical connection must be fused
correctly:
For the operation of frequency converters,
only connect the machine to a power source
with an approved FI circuit breaker (30 mA
RCD - residual current device) of type “B”
that is sensitive to all currents.
DANGER!
Starting machine!
Risk of injury when working on the machine.
The drives of the machine may only be operated
via the designated control box.
Under no circumstances may the connection plugs
of the drives be connected to other power sources.
1
1