Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Measures to be taken in the event of a power failure
48
2021-02-10
After the emergency response
7. If the seriousness of the emergency warrants this,
inform the responsible authorities.
8. Assign specialist personnel to begin rectifying the fault.
WARNING!
Danger of death due to premature restarting!
All persons in the danger zone are at extreme
risk when the machine is switched back on.
Ensure that the danger zone is clear before
switching the machine back on.
9. Check the equipment before switching it back on and ensure
that all safety devices are in place and functioning properly.
40 Measures to be taken in the event of a power failure
40.1 Turning the main switch to position “0”
Fig. 76: Turning the main switch to
position “0”
1. Close the air tap on spray gun.
2. Turn the main switch to position “
0
”.
3. Switch off the air compressor at the rotary switch.
4. Have the power supply connection checked by an expert.
40.2 Discharging mortar pressure
Fig. 77: Mortar pressure at 0 bar
DANGER!
Overpressure on the machine!
When opening machine components, these can fly
open in an uncontrolled manner and injure
the operator.
Only open the machine if the pressure has fallen
to “0 bar”.
DANGER!
Danger of injury due to leaking mortar!
Escaping mortar can lead to injuries to
the eyes and face.
Therefore:
Never look into the spray gun.
Always wear protective goggles.
Always position the machine so that you cannot
be hit should mortar escape.