Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Measures to be taken in the event of a power failure
2021-02-10
49
40.3 Discharging mortar pressure
Fig. 78: Checking the grout pressure
1. Open air tap on the spray gun.
2. Check the mortar pressure gauge (1) to see if the pressure has
fallen to “0 bar”. If necessary, discharge any mortar pressure by
unscrewing the nuts (2) slightly. Cover the working area with tear-
resistant foil.
3. Then tighten the nuts again.
40.4 Switching on the machine again after a power failure
1 3
4 2
Fig. 79: Restart lock
NOTE!
The CMP 30 4.0 is equipped with a starting lock.
In the event of a power failure, the system must be
started as follows.
1. Turn the step switch (1) to “0”.
2. Close the air tap on spray gun.
3. Turn the main switch (2) to the “
I
”
position.
4. Switch on the air compressor at the rotary switch (see Fig. 80).
5. Switch on the machine, press the green pushbutton (4)
control voltage “ON”.
6. Turn the step switch (4) to “4”.
7. The CMP 30 4.0 starts up again as soon as the air valve on
the spray gun is reopened.
NOTE!
In the event of a prolonged power failure,
the CMP 30 4.0 and the material hoses
should be cleaned immediately.
1