43.2 Securing against restarting
DANGER!
Danger of death due to unauthorised restarting!
When working on rotating parts of the machine,
there is a danger of unauthorised switching on of
the electrical supply. This puts those in the danger
area at extreme risk.
Before starting work, switch off all electrical power
supplies and secure them against being switched
back on again.
If the protective covers are removed for cleaning
purposes, it is essential that they be properly
reattached when work is finished.
43.3 Cleaning the CMP 30 4.0
Fig. 88: Mixing tube cover
CAUTION!
Water can enter sensitive machine parts!
Before cleaning the machine, seal all openings
where water could enter and impair the safety
and functions of the machine (e.g.: electric motors
and control boxes).
NOTE!
Do not aim the water jet at electrical components,
such as the gear motor or control box.
If the mixing tube is removed, close the mixing
tube adapter with the mixing tube cover (1).
Do not clean the drying zone with water.
43.4 Disconnect mortar hose
Fig. 89: Mortar pressure at
“
0
”
bar
1. Check the mortar pressure gauge (1) to see if the pressure has
fallen to 0 bar.
DANGER!
Overpressure on the machine!
When opening machine components, these can
fly open in an uncontrolled manner and injure
the operator.
Only open the machine if the pressure has fallen
to “0” bar.
2. Release cam lever (2) and uncouple mortar hose from
the mortar pressure gauge.
1
2