Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Switching off the CMP 30 4.0
2021-02-10
61
Fig. 98: Changing the pump
1. Undo the flanged nuts (1).
2. Remove support plate with pressure flange.
3. Remove the rotor and stator (2).
4. Insert new rotor and stator.
5. Place support plate with pressure flange on top and tighten
collar nuts (1).
6. When inserting the pump, make sure it is properly seated.
NOTE!
Only store assembled pumps (rotor in stator)
for a few days, since longer storage may cause
the rotor and stator to become inseparably joined.
45 Switching off the CMP 30 4.0
1 2
Fig. 99: Switching off
1. Switch off the machine, press the red pushbutton (1) so
the control voltage is “OFF”.
2. Turn the main switch (2) to the position “
0
”.
46 Measures to be taken if there is a risk of frost
CAUTION!
Damage due to frost!
Water that expands on freezing inside
the component can cause serious damage.
Therefore:
Carry out the following steps when the pump
is not operating and there is a danger of frost.
46.1 Uncoupling the water hose
Fig. 100: Uncoupling the water hose
1. Close external water supply.
2. Disconnect the water hose from the water inlet (1).
2
1
1