Container Mixing
Pump CMP 30 4.0
Part 2: Overview –
Operation – Spare Part Lists
Maintenance
66
2021-02-10
Fig. 109: Dirt trap screen
3. Unscrew the sealing cap (4) from the pressure reducer.
4. Remove and clean the dirt trap screen (5) (monthly).
5. Replace the dirt trap screen if dirt is severe.
6. Insert strainer and screw on sealing cap.
7. Put the polyamide hose (3) back into the screw connection.
Screen for pressure reducer: Item number 20156000
47.8 Safety valve air compressor
Fig. 110: Safety valve
Check whether the safety valve on the air compressor opens
at 4.0 bar against a completely closed air line.
47.9 Checking the sealing unit
Fig. 111: Sealing unit
Refill the sealing unit with standard gear grease.
Weekly check at the sight glass of the sealing unit.
47.10 Lubricating the mixing motor
Fig. 112: Mixer motor
Lubricate the mixer motor every six months with standard
gear grease.
5
4
1