FERRO 100 II Part 2 Overview – Operation - Spare parts lists
EMERGENCY STOP situation, end of work or interruption of
work
2018-03-26
33
23.3
Remote control
Fig. 46: Connecting the remote control
Disconnect the dummy connector (1) from the control box and
insert the cable from the cable drum using the remote control.
Fig. 47:
Remote control
The automatic mode can be switched on or off with the push button
(2) on the remote control.
Fig. 48:
Correction of consistency
For optimal consistency in the mortar outlet, the addition of water
by adjusting the amount of water on the diaphragm valve (3) can
be corrected, if necessary. The amount of water is evident on the
floater (4) of water flow meter.
23.4
Lamp test
Fig. 49:
Lamp test
NOTE!
Please press the push button “lamp test” (1) at least
once per shift to check the function of the signal
lamps. Faulty operation of the system can thus be
prevented.
24 EMERGENCY STOP situation, end of work or interruption of
work
Fig. 50: Switching off
The machine can be switched off via remote control, main
reversing switch (1) or with the push button "OFF" control voltage
(2) ON / OFF.
The EMERGENCY OFF (3) button is to be pressed in emergency
situations.
NOTE!
After the end of work, the power supply and the
water supply must be disconnected from the
machine.
1
2
4
3
2
1
3
1