FERRO 100 II Part 2 Overview – Operation - Spare parts lists
Rest
2018-03-26
41
26.11 Detach coupling connections
Fig. 57: Loosen coupling
If the blockage cannot be released:
Cover coupling connections with tear-proof film.
Loosen cam leaver and hose connections.
NOTE!
Clean material hoses immediately.
Dislodge the blockage by tapping or shaking at the place where the
blockage is located.
If necessary, rinse the material hoses with a water hose and then slurry
again.
26.12 Interruption in conveying
NOTE!
Avoid production interruptions as much as possible.
27 Rest
Fig. 58: Switching off
NOTE!
Always
pay attention to
the setting time of the material to be
processed and the
external temperatures.
The machine can be switched off via remote control, main reversing switch
control voltage ON / OFF or with the main switch.
Clean the system and material hoses depending on the setting time of the
material.
28 Cleaning
28.1
Run the machine empty
Fig. 59:
Run the machine empty
The machine has to be cleaned daily.
In addition, before end of work:
Turn the selector switch (1) to position “6” (empty the mixer).
Star wheel lock and vibrating unit stop.
The mixer conveys material in the pump container till the pilot lamp “No
Material” lights up.
The machine shuts down after 25 seconds.
NOTE!
Never let the pump run dry as this reduces the
service life of the pump.
1