FERRO 100 II Part 2 Overview – Operation - Spare parts lists
Cleaning the mixer
2018-03-26
43
29 Cleaning the mixer
29.1 Safety shutdown at the mixing tube
Fig. 64:
Cleaning the mixer
Remove the water hose (1) from the mixing tube.
Release quick fasteners (2) and remove mixing tube.
Pull the mixing shaft out of the mixing tube and clean parts.
NOTE!
Safety shutdown (3).
If the mixing tube is removed, the booster pump is
in operation only for cleaning purposes of the
machine.
If the control lamp flashes red, the control voltage
must be switched off (5) or restarted (6).
Fig. 65:
Cleaning the pump container
NOTE!
Do not clean dry section with water.
Do not clean FERRO II with a steam jet or high-
pressure cleaner.
Connections and gaskets will be damaged because
of this.
30 Cleaning the machine and pump container
Fig. 66:
Cleaning the pump container
Fold up the cover (1) of the pump container.
At the same time, this also acts as a protective cover for the dry
zone.
Fig. 67: Connecting the water hose
Water
Connect the water hose (2) to the water extraction valve (3).
1
3
2
3
2
6
5
1
2
4