PFT G 5 c FU 230
15
Initial Start
01.2005
____________________________________________________________________________________________________________
________________________________________________________________________________________
Knauf PFT GmbH & Co. KG
Telephone
09323 / 31-760
PO Box 60
Telefax
09323 / 31-770
D-97343 Iphofen
Internet
www.pft.de
________________________________________________________________________________________
- Transport assemblies as near as possible to the object to work with
(assembly see transport).
- Lock the castor before putting the machine into service.
- Connect water intake to ¾" hose. Open water intake to vent and clean the hose
line. Close water intake.
- Connect water hose to inlet of water manifold / water pump.
Close drainage valves on water manifold
- at a water pressure below 2.5 bar, the installed water pump can be used to
increase pressure.
WARNING!
When working using the water barrel, the suction inlet with filter screen
(item no. 20 47 50 00 ) must be mounted (bleed water pump).
The machine may only be connected to a 16 A worksite switchgear assembly with
approved 30 mA FI safety switch. The connection cable must be equivalent to the
H07 RN-F 3x2.5 mm
2
version.
We always recommend using the PFT power cable 3x2.5 mm², 25 m with earthling
plug and CEE coupling (item no. 20 42 34 20).
Before the cabinet box is powered, the following must be observed:
- Turn off main reversing switch (position “0”, lockable)
- Turn star wheel switch to “0” position
- Pull out blind plug
Connect pump motor (10-pin plug)
Switch off compressor (pull out plug)