Operate red “OFF” pressure switch (machine stops)
Connect air hose to air manifold and spraying gun
Switch on compressor (insert plug)
Connect all required mortar hoses to each other and flush with water to avoid hose
blocks (do not leave water in hoses). To do so, use cleaner coupling (in tool bag).
If mortar quality is unknown, pour approx. 3 liters lime or plaster slurry into the first
hose after the machine.
WARNING!
Make sure that the coupling is clean and correctly joined.
Connect hoses to the mortar pressure gauge and again observe the mortar hose
seal.
Connect spraying gun (finishing coat gun or crimp valve gun) to mortar hose.
Press selector switch “ON” and open air tap on spraying gun. The machine starts;
cleaning can now be started.
At first, mortar of thin consistency emerges at the spraying gun, then mortar of the
correct consistency. If required, use the needle valve for making further adjustments.
Open and close the air tap on the spraying gun to switch the machine on and off.