Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Description
4.5.2
Control box item no. 00254666
6
1
3
2
4
5
12
11
10
9
8
7
[1]
The master switch is also the emergency-stop switch
[2]
Water supply button
[3]
Selector switch booster pump "manual-0-automatic"
[4]
Selector switch level sensor, at the same time control lamp no
material
[5]
Green control lamp, only lights up if the supply line is OK and
the tilt switch has not tripped
[6]
Main terminal
[7]
Dummy connector / connection for remote control
[8]
Yellow control lamp, no water
[9]
Red control lamp, motor protection switch activated
[10] Release the pump (reverse operation)
[11] Selector switch star wheel "manual-0-automatic"
[12] Pushbutton for control voltage "ON/ OFF"
13
14
15
17
16
Figure 12: Assembly unit control box
[13] CEE mounted socket for connection of air compressor
[14] Panel-mounted safety socket
[15] Connection for level sensor in the material hopper
[16] CEE mounted socket for connection of pump motor
[17] CEE mounted socket, controlled for connection of booster
pump
page 22 / 72