Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
5.1.4
Safety system
1
Figure 23: Inclination switch
Inclination switch (1) in the terminal box of the geared motor.
The inclination switch triggers as soon as the quick closure is
opened and the geared motor is tilted on the side.
If the machine in on rough terrain, the inclined position of the
machine can also trigger the inclination switch.
5.1.5
System monitoring
1
Figure 24: Level sensor in the material
hopper
NOTE
As soon as there is no more material at the level sensor
(1), the machine switches off.
2
Figure 25: Deactivate level sensor
The machine can also be operated without a level sensor.
If the level sensor selector switch (2) is set to the "left"
position, the level sensor is disabled.
This function is necessary to empty and clean the
machine, for example.
5.1.6
Mortar pressure gauge
Figure 26: Mortar pressure gauge
WARNING
Operating pressure too high!
Machine parts can open in an uncontrolled manner and
injure the operator.
Do not operate the machine without mortar pressure
gauge.
Only use mortar hoses with a permissible operating
pressure of at least 40 bar.
The burst pressure of the mortar hose must reach at
least 2.5 times the value of the operating pressure.
page 30 / 72