Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
5.3.3
Connecting the power supply
Figure 29: Connect power supply.
1. Only connect the machine to three-phase current with 400 V.
DANGER
Danger to life from electric current!
The electrical connection must be fused correctly:
Only connect the machine to a power source with
an approved RCD (residual current device) of type A
(30 mA).
5.3.3.1 Connecting the individual connectors
1
4
3
2
Figure 30: Power connections
WARNING
Danger to life from rotating parts!
Improper operation may lead to serious damage to
persons or property.
The respective drive (motors) must be operated only
with the control box of the machine.
1. Connect the power supply for the air compressor (1).
2. Connect the power supply for the booster pump (2).
The booster pump is necessary if the water pressure falls
below 2.5 bar during running operation of the machine.
3. Connect the power supply for pump motor (3).
4. Connection for level sensor in the material hopper (4).
5.3.4
Connecting the water supply
1
3
2
Figure 31: Closing the drainage cocks
1. Close the water draining cocks (1) at the water fitting.
2. Close the water sampling valve (2).
3. Close the water draining cock (3) on the booster pump.
page 32 / 72