Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
5
4
3
Figure 32: Connecting the water
4. Clean the water hose (3) from the water supply and bleed.
5. Connect the water hose (3) to the water inlet (4).
6. Remove the water hose (5) from the mixing tube.
7. Open the water tap from the water supply line.
NOTE
Use only clean water free of solids. The minimum pres-
sure is 2.5 bar when the machine is running.
Observe the Drinking Water Protection Ordinance in
Part 1
NOTE
Never let the pump run dry as this reduces the service life
of the pump.
5.3.4.1 Connection of water from water tank
Figure 33: Water tank
Figure 34: Filter screen
NOTE
When working with water from the barrel, the inlet strainer
must be fitted with a filter screen (item no. 00136619)
(Bleed the booster pump)
NOTE
The booster pump must not run dry to avoid any damage!
page 33 / 72