Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
5.14.6.3 Switching on the machine after removing a blockage
1
4
5
7
6
2
3
Figure 81: Switching on the machine
again
1. Turn the main switch (1) to "ON".
Green control lamp (2) lights up
2. Turn the level sensor selector switch (3) to "right" position.
3. Turn the booster pump selector switch (4) to the "AUTO" position.
4. Turn the selector switch star wheel (5) to the "AUTO" position.
5. Switch the machine one by pressing the green pushbutton (6)
control voltage "ON".
6. Let the machine run for a short while without mortar hoses.
7. As soon as material emerges from the pressure flange, press the
red pushbutton (7) control voltage "OFF".
8. Apply wallpaper paste to the cleaned mortar hoses and connect to
the machine and spray gun.
9. Switch the machine one by pressing the green pushbutton (6)
control voltage "ON".
10.The machine starts again as soon as the air tap at the spray gun is
re-opened.