Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
5.3.5
Switching on the machine
1
3
4
2
Figure 35: Switching on the machine
1. Turn the main switch (1) to "ON".
Green control lamp (2) lights up
NOTE
The green control lamp (2) only lights up if the supply line
is OK and the tilt switch has not tripped.
2. Turn the booster pump selector switch (3) to the "AUTO" position.
3. Turn the level sensor selector switch (4) to "left" position.
5.3.5.1 Setting the water quantity
1
Figure 36: Press the water supply
button
2
3
4
Figure 37: Setting the water quantity
1. Press the water supply button (1) to adjust the water quantity.
2. At the same time, adjust the anticipated amount of water required
at the needle valve (2), which can be seen at the cone (3) in the
sight glass of the water flow meter (4).
NOTE
Observe the specifications of the material manufacturer
when setting the water factor.
Every interruption to the spraying process causes a slight
irregularity in the consistency of the material. This irreg-
ularity normalises by itself as soon as the machine has
been working for a short while.
Therefore it is important not to change the water quan-
tity for each irregularity. Wait until the consistency of the
material has set again.
page 34 / 72