Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
Figure 63: Strainer
6. Open and empty strainer.
NOTE
Make sure that the water fully flows out of the water mani-
fold.
5.12.1
Blowing the water manifold dry
2
1
3
Figure 64: Connecting the air hose
1. Connect air hose (1) with Geka coupling and EWO coupling to the
compressed air flange (2) and to the water inlet (3).
5
7
4
8
6
Figure 65: Blowing the water manifold
dry
2. Turn the level sensor selector switch (4) to "left" position
3. Turn the star wheel selector switch (5) to the "0" position.
4. Turn the booster pump selector switch (6) to the "0" position.
5. Turn the main switch (7) to "ON".
6. Switch on the air compressor using the black switch.
7. Press and hold the water flow button (8) for approx. 15 seconds.
8. The water is now blown out of the manifold with compressed air.
9. Switch off the air compressor at the red switch.
10.Turn the main switch (7) to "OFF".
NOTE
Make sure that the water fully flows out of the water mani-
fold.
page 46 / 72