Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
5.13
Ending work / cleaning the machine
5.13.1
Cleaning
Clean the machine daily at the end of work and in case of
extended breaks.
NOTE
Water can enter sensitive machine parts!
Before cleaning the machine cover all openings in
which no water must enter for safety and functional
reasons (e.g.: electric motors and control cabinets).
Remover the covers completely after cleaning.
5.13.2
Secure against restarting
WARNING
Danger to life from unauthorised restarting!
When working with the machine there is the risk that the
energy supply is switched on without authorisation. This
poses a danger to life for the persons in danger area.
Before starting work, switch off all electrical power
supplies and secure them against being switched back
on again.
If the protective covers are removed for cleaning
purposes, it is essential that they be properly reat-
tached when work is finished.
5.13.3
Deactivate level sensor
1
Figure 66: Deactivate level sensor
In order to clean the machine, set the level sensor
selector switch (1) to the "left" position, otherwise the
machine will receive an empty message via the level
sensor and stop.
If the level sensor is deactivated via the selector switch,
the machine continues to run.
page 47 / 72