Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
5.13.7
Cleaning the mixing tube
1
Figure 72: Opening the motor tilt flange
1. Open the quick closure at the motor tilt flange and tilt the motor.
2. Remove the mixing shaft (1) and clean it.
5.13.7.1 Inserting the mixing tube cleaner
1
2
Figure 73: Inserting the mixing tube
cleaner
1. Take the mixing tube cleaner (1) and cleaning shaft (2) from the
tool box.
Insert the mixing tube cleaner (1) into the mixing tube with
the scrapers pointing downward.
NOTE
When inserting the cleaner shaft ensure that the cleaner
shaft engages correctly in the drive dog in the head of the
rotor and when closing the motor flange.