Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Operation
1
2
Figure 74: Closing the motor tilt flange
5
6
3
4
Figure 75: Cleaning the mixing tube
Cleaning the mixing tube
CAUTION
Danger of crushing at the motor tilt flange!
There is a danger of crushing injuries when closing the
motor tilt flange.
Never reach into the closing range of the motor tilt
flange.
1. Close the motor tilt flange (1) and lock using the quick closure (2).
2. Turn the main switch (3) to "ON".
3. Turn the level sensor selector switch (4) to the "left" position
4. Switch the machine one by pressing the green pushbutton (5)
control voltage "ON".
5. Allow the machine to run for approx. 5 - 10 seconds until the mixing
tube is cleaned.
6. Switch off the machine by pressing the red pushbutton (6) control
voltage "OFF".
7. Turn the main switch (3) to "OFF".
8. Open the quick closure (2) and tilt the motor.
9. Take mixing tube cleaner with cleaner shaft out of the mixing tube.
5.13.7.2 Inserting the mixing shaft
1
3
2
1
Figure 76: Inserting the mixing shaft
1. Insert mixing shaft (1) and ensure correct positioning at the rotor
(2).
2. When closing the tilt flange ensure that the mixing shaft (1)
engages properly into the drive dog (3).
3. Close the quick closure at the mixing tube.
5.13.8
Cleaning the material hopper
The inside of the material hopper can be cleaned with a
water hose after having been emptied completely.
page 51 / 72