Mixing pump G 4 X Super / G 4 X XL / Part 2 Overview, operation and service
Maintenance
6.4.2
Air filter compressor
1
2
Figure 83: Remove air compressor
Implementation by a service technician
Remove air compressor from bracket:
1. Loosen air hose (1) from the air compressor.
2. Fold compressor bracket (2) upwards and remove air compressor
from bracket.
NOTE
Take the weight of the air compressor into consideration.
3
Figure 84: Filter of the air compressor
3. Remove filter cover.
4. Take out the filter.
5. Blow through the filter from the inside to the outside or tap it.
6. Replace the filter in case of heavy contamination.
7. Insert the filter with the solid side of the filter (3) pointing inwards.
Figure 85: Filter cover opening
8. Replace filter cover.
Opening of the filter cover is at the bottom.
6.4.3
Plastic screen in the strainer
1
2
Figure 86: Plastic screen
Implementation by operator.
1. Remove the closure cap (1) from the strainer.
2. Take out the plastic screen (2) from the strainer (monthly).
3. Clean the screen.
4. Replace the screen if dirt is severe.
5. Refit the screen.
6. Replace the closure cap.
page 63 / 72