PFT continuous mixer HM 2002 Overview - Operation - Spare parts lists
Work on troubleshooting
30
2017-03-14
Personnel
The work for rectification of faults described here can be carried
out by the operator, unless marked otherwise.
Some works must be carried out only by specially trained skilled
personnel or exclusively by the manufacturer. Information on
this can be found in the description of the individual faults.
Work on the electrical system must, in principle, be carried out
only by electricians.
32.4 Table of faults
Fault
Possible cause
Solution
Rectification by
Machine does
not start
Current
Power supply not in order
Repair power supply
Service engineer
“On” switch not pressed
Press the switch
Operator
RCCB was triggered
Reset RCCB
Service engineer
Machine does
not start
Material
Excessively thickened material in
mixing tube
Empty the mixing tube and start
again
Operator
Excessively dry material in mixing
tube
Empty the mixing tube and start
again
Operator
Water is not
flowing
Solenoid valve (hole in membrane
blocked)
Clean solenoid valve
Service engineer
Solenoid coil defective
Change solenoid coil
Service engineer
Water inlet on the middle body
blocked
Clean the water inlet on the middle
body
Operator
Needle valve closed
Open needle valve
Operator
Cable to solenoid valve defective
Replace cable to solenoid valve
Service engineer
Mixing motor
does not start
Mixing motor defective
Replace the mixing motor
Service engineer
Connection cable defective
Change connection cable
Service engineer
Machine
stops after a
short while
Water inlet screen contaminated
Clean or replace strainer
Operator
Hose connection or water pipe too
small
Increase
dimensions
of
hose
connection or water pipe
Operator
Water inlet pipe too long or inlet
pressure too low
if possible, attach an additional
booster pump
Service engineer