PFT SCREW MIXER HM 24 Overview – Operation – Spare Parts Lists
Putting the machine into operation
2017-08-07
23
18.1 Water from a water barrel
Booster pump AV3000/1 (1) item number 00493686
The booster pump which is connected ensures the required water
pressure of minimum 2.5 bar.
NOTE!
When working with water from the barrel,
the inlet strainer must be fitted with a filter strainer
(item no. 00136619) (bleed booster pump).
19 Putting the machine into operation
19.1 Hazardous dust
WARNING!
Danger of health problems due to dust!
Inhaled dust can lead to long-term lung damage
or other health problems.
NOTE!
The machine operator or the person working in the
dusty area must always wear a dust mask when
filling the machine.
The decisions of the Committee for Hazardous
Materials (AGS) can be read in the Technical Rules
for Hazardous Substances (TRGS 559).
1