PFT HM 6 FU 230V HYMIX
9
Setting values and starting up
Status 11.2004
____________________________________________________________________________________________________________
_______________________________________________________________________________________
Knauf PFT GmbH & Co. KG
Telephone 09323 / 31-760
PO Box 60
Fax
09323 / 31-770
D-97343 Iphofen
Internet
www.pft.de
_______________________________________________________________________________________
After the horizontal mixer
PFT HM 6
has been completely fitted and connected, the
following procedure must take place:
Open the silo flap.
Switch on the
PFT HM 6
using the green
ON switch.
Regulate the water quantity on the
needle valve.
Set the rev counter control to the desired mixing time (0.5 to 10 minutes)
Attention!
When changing the time relay, you have to observe K6. The time control on the ma-
chine has to be set to the maximum when running in the remote rev counter mode.
For running the machine without remote rev control, no bridge is required for the relay.
Mortar consistency
The needle valve must be adjusted in such a way that a trowel-consistency mortar
emerges from the mortar outlet of the mixing tube.
Important
Observe the material manufacturer’s guidelines.
Breaks in work
The maximum duration of breaks depends on the materials, and, above all, on the
conditions of the construction site (external temperature, air humidity etc.).