Cleaning and measures upon completion of work
Status 11.2004
____________________________________________________________________________________________________________
_______________________________________________________________________________________
Knauf PFT GmbH & Co. KG
Telephone 09323 / 31-760
PO Box 60
Fax
09323 / 31-770
D-97343 Iphofen
Internet
www.pft.de
_______________________________________________________________________________________
ATTENTION!
Maintenance and assembly work may only be carried out when the machine is without
power (interrupt the power supply).
Cleaning
With a consistent daily operation, the PFT HM 6 needs only to be cleaned at the end of
work.
The cleaning is carried out in 5 stages
1. Close the silo flap.
2. Open the needle valve.
3. As soon as a very diluted mortar emerges, connect the PFT HM 6.
4. Open the screws on the mortar outlet and remove the mortar outlet flange.
5. Remove the mixing shaft and clean with water.
ATTENTION!
No water must reach the bearing or the electrical parts (plug, main switch, terminals
etc.).