background image

 

 

____________________________________________________________________________________________________________  

PFT HM 6 FU 230V HYMIX 

24 

Spare parts list – switch cabinet assembly 

Status 11.2004 

____________________________________________________________________________________________________________  

_______________________________________________________________________________________ 

 

Knauf PFT GmbH & Co. KG 

 

Telephone  09323 / 31-760 

PO Box 60 

 

Fax 

09323 / 31-770 

D-97343 Iphofen 

 

Internet 

www.pft.de 

_______________________________________________________________________________________ 

Pos.  Pcs.  Article no.  Article description 

00 05 35 30  Empty housing HM 6 FU 230 Hymix RAL7032/Struk 

00 02 21 74  Control transformer 230V/400V-42V 70VA without fuses 

00 02 26 48  Frequency converter 230V 4KW 17.6A TYPE: CI 

20 44 81 20  Switching relay 42V 2 reverser  

20 45 27 20  Impulse pause relay 42V 10sec. cycle 

20 44 71 00  Air break contactor DIL 0M 42V 

00 04 43 57  Timer relay 0.5 to 10 minutes for remote rev counter NGZP 31 

00 04 25 99  Motor safety switch 0.63-1A PKZM 0-1 

00 02 14 01  Auxiliary contact NHI-11-PKZO 

10 

00 04 26 02  Motor safety switch 10-16A PKZM 0-16 (P) 

11 

00 05 35 33  Insulated material for motor safety switch 

12 

00 05 35 79  Lock for switch cabinet (Tommy grip) 

13 

00 00 24 69  CEE connector 3 x 32A 6h blue no. 381 

14 

00 02 20 55  CEE built-in socket 4 x 16A 9h blue T121/780 

15 

20 42 64 00  CEE built-in socket 3 x 16A 12h white no.1272 

16 

20 42 72 10  Built-in socket - Schuko grey  

17 

00 02 20 63  Connector for solenoid valve  

18 

00 04 43 56  Remote rev counter 10 kOhm for time relay 

19 

00 05 38 43  Front unit for press button blue/reset M 22 

20 

00 05 38 30  Membranes round for pressure switch 

21 

00 05 38 39  Press button without front unit 

22 

00 05 38 34  Fastening adapter M 22 

23 

00 05 38 35  Contact-element 1 make contact M 22 

24 

00 05 38 86  LED - resistor - additional series resistor 42 V 

25 

00 05 38 79  Luminous element red 12-30V 

26 

00 05 38 75  Front cap for the signal lamp red M 22 

27 

00 05 38 74  Front cap for the signal lamp yellow M 22 

28 

00 05 38 81  Luminous element white 12-30V 

29 

00 05 38 31  Membranes angular for double pressure switch M22-TDD 

30 

00 05 38 32  Luminous push-button key on/off M 22 

31 

00 05 38 35  Contact-element 1 make contact M 22 

32 

00 05 38 36  Contact-element 1 break contact M 22 

33 

20 45 52 03  Main switch 230V 

34 

00 04 46 67 

Pressure compensation disc

 

 

 

 

Summary of Contents for HM 6 FU 230V HYMIX

Page 1: ...OPERATING INSTRUCTIONS BAL NR 00 05 41 39 PFT HM 6 FU 230V HYMIX WE KEEP THINGS MOVING...

Page 2: ...ompany The PFT HM 6 is state of the art It has been designed in such an easy to use manner to provide you with a true assistant in the tough building site conditions These operating instructions shoul...

Page 3: ...Initial inspection after delivery An indispensable task of all fitters who deliver the PFT HM 6 is to check the machine settings after the initial starting up The plant settings can change during the...

Page 4: ..._______________ Knauf PFT GmbH Co KG Telephone 09323 31 760 PO Box 60 Fax 09323 31 770 D 97343 Iphofen Internet www pft de _____________________________________________________________________________...

Page 5: ...____________________________________________________________________________ Knauf PFT GmbH Co KG Telephone 09323 31 760 PO Box 60 Fax 09323 31 770 D 97343 Iphofen Internet www pft de ________________...

Page 6: ...x 09323 31 770 D 97343 Iphofen Internet www pft de _______________________________________________________________________________________ 1 Motor protection control transformer 11 Connection motor ca...

Page 7: ...rocessing guidelines The operating instructions give the following names and signs to particularly important information INFORMATION Special information referring to the efficient use of the machine A...

Page 8: ...trician or by instructed persons under the supervision of an electrician in accordance with elec tro technical regulations 8 Switch on and switch off processes control displays must be observed in acc...

Page 9: ...cing valve 1 9 bar at 1000 l h maximum opening Power connection In accordance with VDE conditions connect the machine only to an assembly for con struction site with stipulated FI safety switch Use po...

Page 10: ...following procedure must take place Open the silo flap Switch on the PFT HM 6 using the green ON switch Regulate the water quantity on the needle valve Set the rev counter control to the desired mixin...

Page 11: ...ial in the mixing tube Water isn t running Machine won t start up Water Solenoid valve hole in the membrane is blocked Inspect and remedy the fault Magnetic coil is faulty Pressure reducing valve is t...

Page 12: ..._________________________________ _______________________________________________________________________________________ Knauf PFT GmbH Co KG Telephone 09323 31 760 PO Box 60 Fax 09323 31 770 D 97343...

Page 13: ..._______________________________________________________________ ATTENTION Maintenance and assembly work may only be carried out when the machine is without power interrupt the power supply Cleaning Wi...

Page 14: ...T HM 6 shall again mix normally Measures in the event of a danger of frost In the event of a danger of frost the water fitting of the PFT HM 6 must be emptied To do this depressurise the water supply...

Page 15: ..._______________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH C...

Page 16: ..._______________________________________________________________________________________________ _______________________________________________________________________________________ Knauf PFT GmbH C...

Page 17: ...____________ _______________________________________________________________________________________ Knauf PFT GmbH Co KG Telephone 09323 31 760 PO Box 60 Fax 09323 31 770 D 97343 Iphofen Internet www...

Page 18: ...__________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf...

Page 19: ...______________________________ Pos Pcs Article no Article description 1 1 20 54 57 01 Drive pin jaw HM3 HM5 25mm hole mi 2 1 20 20 96 03 Threaded pin with hexagon screw M8 x 20 DIN 916 3 1 20 54 57 02...

Page 20: ...__________________________________________________________________________________________________________ _______________________________________________________________________________________ Knauf...

Page 21: ...x4 with 24 holes 9 1 00 05 50 58 Seal for motor flange 10 1 20 10 10 10 Folding split pin D 4 5 with ring 11 1 00 03 99 56 Mixing tube HM 6 RAL2004 12 3 20 20 99 21 Flanged nut M16 DIN 6331 galvanised...

Page 22: ...____________________________________________________________________________________________________________ _______________________________________________________________________________________ Kna...

Page 23: ...20 10 10 10 Splint D 4 5 with ring 12 2 00 05 81 34 Hinged bolt for HM 6 galvanised 13 1 00 03 92 86 Fitting block red metal DK 06 FN 1 2 E 14 1 00 04 04 26 Regulator valve insert complete red metal...

Page 24: ...____________________________________________________________________________________________________________ _______________________________________________________________________________________ Kna...

Page 25: ...O 10 1 00 04 26 02 Motor safety switch 10 16A PKZM 0 16 P 11 2 00 05 35 33 Insulated material for motor safety switch 12 1 00 05 35 79 Lock for switch cabinet Tommy grip 13 1 00 00 24 69 CEE connector...

Page 26: ...nt consumption 6 35 A Number of revolutions 280 min 1 Dims Length of everything 2005 mm Width of everything 330 mm Total weight ca 150 kg Power connection Three phase 230 V 50 Hz 16 A Supply 5 x 2 5 m...

Page 27: ..._______________________________________________________________________ PFT HM 6 FU 230V HYMIX 25 Technical data Status 11 2004 ________________________________________________________________________...

Page 28: ...WE KEEP THINGS MOVING Knauf PFT GmbH Co KG Postfach 60 D 97343 Iphofen Einersheimer Stra e 53 D 97346 Iphofen Telephone 0 93 23 31 760 Fax 0 93 23 31 770 Email info pft iphofen de...