6.3 Weekly inspection
Fig. 13: Oil level
Check the oil level and top up if necessary, but do not exceed the maximum
level (Fig. 13). An oil level below the minimum can lead to serious damage.
PROTECTIVE OILS FOR RECIPROCATING COMPRESSORS
(for room temperatures from +5C to +25C)
SHELL Rimula D Extra 15W-40
AGIP Dicrea 100 API CM-8X
BP Energol CS100 CASTROL Aircol PD100
ESSO Exxc Olub H150 MOBIL Rarus 427
IP Calatia Oil ISO 100 TOTAL Dacnis P100
FUCHX Renolin 104L VG100
At room temperature below +5C°: ISO 68
At room temperature above +25°C: ISO 150
Fig. 14: Condensate
Open the valve under the tank and under the pressure reducer
– if installed (Fig. 14) – to drain the condensation water.
As soon as the air begins to flow out, close the valve again.
6.4 Monthly inspection or more frequently
Fig. 15: Intake filter
When operating the compressor in a particularly dusty environment,
remove the suction filter and replace or clean the filter element (Fig. 15).
Never operate the compressor without an intake filter.
The ingress of foreign bodies or dust can seriously damage
the internal components.