Part 2 EC Declaration of Conformity Overview – Operation
Intended use of fitting block
18
2020-03-25
Fig. 22
Cleaner coupling 13 female part Geka Art.No. 00087597
Fig. 23
Air hose DN9 Ewo male part | Ewo female part - 16 m Art.No. 00008521
Fig. 24
00094898
Spraying gun powercoat DN13 VA4
1500 Ewo, handle, stainless steel
00098703
Belt for spraying gun RITMO powercoat
18 Intended use of fitting block
18.1 Purpose of fitting block
The equipment has been designed and constructed only for
the intended use described below.
Application range!
Primary use for water and neutral, non-adhesive
liquids. Also suitable for air and neutral non-
flammable gases.
Maximum operating pressure (initial pressure)
16 bar.
After-pressure infinitely adjustable
from 1.5 to 6 bar.
Smallest possible initial pressure 2.5 bar.
Minimum pressure gradient (initial/after-pressure)
1 bar.
Maximum media and ambient temperature 75°C.
Installation position unimportant,