Part 2 EC Declaration of Conformity Overview – Operation
Connection to the 230V power supply
2020-03-25
31
30.4 Water supply connection
Fig. 40: Water connection
4
5
Fig. 41
:
Cleaning the nozzle
1. Check whether the water inlet screen in the water inlet (1)
is clean.
2. Clean and bleed the water hose (2) for the water mains supply.
3. Connect the water hose (2) to the water inlet (1).
4. Remove the water hose (3) from the mixing tube.
NOTE!
Only use clean water that is free of particulates.
The minimum pressure is 2.5 bar when the
machine is running.
Observe the Drinking Water Protection Ordinance
in Part 1.
NOTE!
Never allow the pump unit to run dry, since
this will significantly shorten its service life.
5. Remove nozzle (4) from rubber mixing tube and clean
with mandrel (5).
30.5 Water from water barrel connection
Fig. 42: Booster pump
Fig. 43: Inlet strainer with filter screen, cpl.
Booster pump AV3000/1 (1) item number 00493686
The booster pump which is connected ensures the required water
pressure of minimum 2.5 bar.
NOTE!
When working with water from the barrel, the
inlet strainer must be fitted with a filter strainer
(item no. 00136619) (bleed booster pump).
NOTE!
Never allow the pressure booster pump to run dry,
since this will significantly shorten its service life.
3
1
2
1