Part 2 EC Declaration of Conformity Overview – Operation
Working with pastes
40
2020-03-25
43.3 In the event of a work stoppage / pause
1
2
Fig.69: Closing the air valve
Fig.70: Switching off
1. Release the handle (1) on the sprayer
2. The machine stops
3. Close the air valve (2) when the nozzle on the sprayer is freely
blown
4. The air compressor switches off (must be on pressure switch-
off)
5. Switch off the machine at the pump motor selector switch (3)
(position "0").
6. Switch off the air compressor
44 Working with pastes
44.1 Mortar pressure gauge
Fig. 71: Mortar pressure gauge
DANGER!
Operating pressure too high!
Machine parts can jump open uncontrolled and
injure the operator.
Do not operate the machine without a mortar
pressure gauge.
Only operate delivery hoses with an approved
operating pressure of at least 40 bar.
The burst pressure of the mortar hose must be
at least 2.5 times the operating pressure.
44.2 Close water inlet
Fig. 72: Close water inlet
1. Close water inlet with blind cover (1).
3