Part 2 EC Declaration of Conformity Overview – Operation
Applying material
2020-03-25
43
47.3 Switching on the air compressor
Fig.79: Air compressor
3. Switch on air compressor (air compressor PFT LK 402 IV Art.No.
00233174).
4. As soon as the air compressor has built up pressure in the pipe
system, it switches off via the pressure cut-off.
DANGER!
The air compressor should not be connected to the
control box of the RITMO POWERCOAT.
47.4 Operation without water
1
3
2
Fig. 80: Switching on
Turn selector switch (1) to position "without water" to the
right.
Turn potentiometer (2) for motor speed / material quantity
to position 10 (readjust as required).
Turn selector switch (3) rotation pump motor to the right.
48 Applying material
DANGER!
Danger of injury due to leaking mortar!
Escaping mortar can lead to injuries to the eyes
and face.
– Never look into the spray gun.
– Always wear protective goggles.
– Always position the machine so that you cannot
be hit should mortar escape.
NOTE!
The maximum pumping distance depends primarily
on the flow characteristics of the mortar.
Heavy, coarse-grained mortar does not flow well.
Fluid materials have good flow characteristics.
If the specified operating pressure is exceeded,