Part 2 EC Declaration of Conformity Overview – Operation
Replacing the pump / Cleaning the pump
2020-03-25
57
56 Replacing the pump / Cleaning the pump
56.1 Placing the machine on its rear
Fig. 100: Turning over the machine
DANGER!
Danger of death due to unauthorised restarting!
When working on the machine, there is a danger of
unauthorised switching on of the electrical supply.
This puts those in the danger area at extreme risk.
Therefore:
Before starting work, switch off the electrical
power supply and secure it against being
switched back on again.
Interrupt the power supply by removing
the connection cable.
NOTE!
For easier pump replacement / pump cleaning,
the RITMO can be placed on its rear.
56.2 Removing the pump unit
1
2
3
Fig. 101: Removing the pump unit
1. Undo screw (1) at the pressure flange (2).
2. Remove mortar pressure gauge with pressure flange (2) and
pump unit (3).
5
4
Fig. 102: Cleaning the remixer
3. Pull the remixer (4) out of the remixer housing (5) and clean it.