Mixing pump RITMO L plus FC-230V Overview – Operation
Sound power level
2020-11-09
11
6.6 Compressor DT4.8
Specification
Value Unit
Compressor output
0.080 Nm³/min
6.7 Operating requirements
Ambient conditions
Specification
Value Unit
Temperature range
2 - 45 °C
Relative humidity (maximum)
80 %
Operating period
Specification
Value Unit
Maximum continuous operating period
8 hours
6.8 Connection values for water
Fig. 1: Water connection
Specification
Value Unit
Operating pressure, min.
2.5 bar
Connection
1/2 inches
7 Sound power level
Guaranteed sound power level L
WA
78 dB (A)
8 Vibrations
Weighted effective acceleration value to which the upper limbs are exposed = < 2.5 m/s²
9
EMC test
The machine has been EMC tested and complies with the strict requirements of EMC Directive filter class B.
The control box is equipped with a line filter.