Mixing pump RITMO L plus FC-230V Overview – Operation
Connections RITMO L plus
2020-11-09
17
16 Connections RITMO L plus
16.1 Connections for water, mortar hose and air
Fig. 14: Connections
1. Air connection to spray gun (1).
2. Water connection from water supply (2).
3. Mortar hose connection (3) to mortar pressure gauge.
17 Operating modes
17.1 Pump motor selector switch
Fig. 15:
Operating modes of
pump motor
The pump motor has three operating modes:
Selector switch position “0”:
The machine is switched off.
Selector switch (latching):
The machine starts up when the main switch is switched on.
Selector switch left (spring return):
The pump motor goes into reverse, thereby relieving the pump
and locking other functions.
17.2 Water selector switch
Fig. 16:
Water selection switch
The RITMO can be used for two application areas:
Selection switch (latching):
The machine is operated without water.
Use as pump.
Selector switch left (latching):
The machine is operated with water.
Use as mixing pump.
17.3 Potentiometer
Fig. 17: Potentiometer
Potentiometer for motor speed / delivery rate:
By turning the potentiometer (1) to the right to a higher number, the
engine speed is increased and thus also the delivery rate.
1
2
3
1